94
6.5.8 Pilot Interface Block
The pilot interface block has been added to control the FASTER status monitor
which is a Java-based software. This block collects a series of variables and send it via
UDP connection to the EPIA EN15000 which runs the FASTER status monitor. The
software displays a series of three lights and four numerical values:
System Status, continuously scans the UDP port for packets, when the system
is down (PC/104+ powered off) a red light is presented instead of green one;
Acquisition Status, shows the camera arm switch position, green light means
that the camera is enabled and ready to acquire images;
GPS Status, reads the GPS sentence counter and shows a green light when
GPS receiver is working correctly, in addition a numeric string inside the
light shows the GPS quality value;
Numerical displays show the aircraft position, altitude, speed and the number
of acquired frames.
The block scheme is presented in Figure 77 and the FASTER system monitor in Figure
78.
Figure 77: FASTER status monitor block scheme